PARTICULATE MATTER CONCENTRATIONS AND RELATED HEALTH EXPOSURE IN SELECTED FIRE STATION AND RESIDENTIAL BUILDING.

Opis bibliograficzny

PARTICULATE MATTER CONCENTRATIONS AND RELATED HEALTH EXPOSURE IN SELECTED FIRE STATION AND RESIDENTIAL BUILDING. [AUT.] JAKUB PACZKOWSKI, KAROLINA BRALEWSKA. Zeszyty Naukowe SGSP. DOI: 10.5604/01.3001.0055.5441
Skopiowane!
Kliknij opis aby skopiować do schowka

Szczegóły publikacji

Rok:2025
Język:angielski
Charakter formalny:Artykuł w czasopismie
Typ MNiSW/MEiN:Praca Oryginalna

Streszczenia

The objectives of this study were: to investigate and compare the mass concentration of size-resolvedparticulate matter (PM1, PM2.5, PM4, PM10, and PM35) in indoor air of three rooms of a selected firestation in Poland (i.e. common room, laundry room, and garage); to compare them with the massconcentration of size-resolved PM in a single-family residential building; and to estimate andcompare the health exposure of occupants of these two building types related to measured PMconcentrations. At each point, measurements were conducted for 12 hours a day for 7 days in heating(26/01/2025–24/02/2025) and non-heating (27/05/2025–27/06/2025) seasons using Grimm 11-Daerosol spectrometer (optical method). As indicated by the data, elevated concentrations of PM wereobserved in both the fire station and the single-family house during the heating season whencompared to the non-heating season. During the heating season, the mean PM concentrationsranged from 17.1 to 68.0 μg/m3 and 17.5 to 48.4 μg/m3, while during the non-heating season, theyranged from 6.8 to 42.4 μg/m3 and 9.2 to 35.5 μg/m3 for the fire station and single-family house,respectively. At each measurement point, with the exception of the laundry room during the heatingseason, the majority of the PM mass was accumulated as coarse particles (55% to 72%). The exposureassessment demonstrated that the highest values of PM deposition in the lung alveoli were recordedfor the laundry room, garage, and single-family house during the heating season and for the laundryroom during the non-heating season. The results obtained in this study can be used in future studiesto assess the health risks of firefighters exposed to air quality inside fire stations. They can also beused to designate directions for further research in this area.

Open Access

Tryb dostępu:otwarte czasopismo

Identyfikatory

ISSN: 0239-5223
e-ISSN: 2720-0779
BPP ID: (7, 9056) wydawnictwo ciągłe #9056

Metryki

70,00
Punkty MNiSW/MEiN
0
Impact Factor
0
Index Copernicus
0
Punktacja wewnętrzna

Eksport cytowania

Wsparcie dla menedżerów bibliografii:
Ta strona wspiera automatyczny import do Zotero, Mendeley i EndNote. Użytkownicy z zainstalowanym rozszerzeniem przeglądarki mogą zapisać tę publikację jednym kliknięciem - ikona pojawi się automatycznie w pasku narzędzi przeglądarki.

Skopiowane!

Informacje dodatkowe

Status:przed korektą
Rekord utworzony:29 grudnia 2025 21:26
Ostatnia aktualizacja:29 grudnia 2025 21:32