The Influence of Hydrogen on the Indications of the Electrochemical Carbon Monoxide Sensors.

Opis bibliograficzny

The Influence of Hydrogen on the Indications of the Electrochemical Carbon Monoxide Sensors. [AUT.] MAJDER-ŁOPATKA MAŁGORZATA, WĘSIERSKI TOMASZ, DMOCHOWSKA ANNA, SALAMONOWICZ ZDZISŁAW, POLAŃCZYK ANDRZEJ. Sustainability. DOI: 10.3390/su12010014
Skopiowane!
Kliknij opis aby skopiować do schowka

Szczegóły publikacji

Źródło:
Rok:2020
Język:angielski
Charakter formalny:Artykuł w czasopismie
Typ MNiSW/MEiN:inne

Streszczenia

This article examines electrochemical carbon monoxide (CO) sensors used as mobile devices by rescue and firefighting units in Poland. The conducted research indicates that the presence of chlorine (Cl2), ammonia (NH3), hydrogen sulfide (H2S), hydrogen chloride (HCl), hydrogen cyanide (HCN), nitrogen (IV) oxide (NO2), and sulfur (IV) oxide (SO2) in the atmosphere does not affect the functioning of the electrochemical CO sensor. In the case of this sensor, there was a significant cross effect in relation to hydrogen (H2). It was found that the time and manner of using the sensor affects the behavior in relation to H2. Such a relationship was not recorded for CO. Measurements in a mixture of CO and H2 confirm the effect of hydrogen on the changes taking place inside the sensor. Independently of the ratio of H2 to CO, readings of CO were flawed. All analyses showed a significant difference between the electrochemical CO sensor readings and the expected values. Only in experiments with a 1:3 mixture of CO and H2 was the relative error less than 15%. The relative error in the analyzed concentration range for a sensor with an additional compensation electrode ranged from 7% to 38%; for a sensor without this electrode, it ranged from 23% to 55%. It was ascertained that in the cases of measurements for tests carried out at higher concentrations of H2 in relation to CO, a sensor with an additional electrode is significantly better (more accurate) than a sensor without such an electrode. Differences at the significance level p = 0.01 for measurements made in the CO:H2 mixture at a ratio of 1:3 were ascertained.

Identyfikatory

ISSN: 2071-1050
BPP ID: (7, 8280) wydawnictwo ciągłe #8280

Metryki

100,00
Punkty MNiSW/MEiN
0
Impact Factor
0
Index Copernicus
0
Punktacja wewnętrzna

Eksport cytowania

Wsparcie dla menedżerów bibliografii:
Ta strona wspiera automatyczny import do Zotero, Mendeley i EndNote. Użytkownicy z zainstalowanym rozszerzeniem przeglądarki mogą zapisać tę publikację jednym kliknięciem - ikona pojawi się automatycznie w pasku narzędzi przeglądarki.

Skopiowane!

Informacje dodatkowe

Liczba arkuszy wydawniczych:100.00
Status:przed korektą
Rekord utworzony:6 lipca 2023 23:52
Ostatnia aktualizacja:6 lipca 2023 23:52